Tools /
ICSR Studio
Open an individual case safety report as E2B XML, HTML, RTF or PDF, check it, correct it, compare it with a follow-up, and export it in the format you need. Everything runs in your browser.
Case files stay on your device. Files are read in the browser and nothing is uploaded or stored. After it loads, the page makes no network requests: its security policy allows connections only to this site. Closing the tab clears loaded cases. Only open case data here if your organisation's rules allow you to process it on this computer.
What it does
- Import: ICH E2B(R3) XML, E2B(R2) XML (best effort), and HTML, RTF or PDF listings and forms. Drop several files at once.
- Export: E2B XML, ICH listing HTML and RTF, EudraVigilance compact PDF, ICH listing PDF, CIOMS I PDF, JSON, or a ZIP of all formats.
- Edit: correct identification, sender, patient, reporters, reactions, drugs and comments. Coded fields (sex, outcome, drug role, action taken, qualification, sender type, report type) are chosen from the ICH code lists, so an edit always resolves to a real code.
- Check: a live checklist of the E2B(R3) mandatory data elements the tool tracks, plus any coded field that did not resolve to an ICH code.
- Compare: with two or more cases loaded, see what changed, was added or was removed between any two, for example an initial report and its follow-up.
- New case: start a case from scratch with one blank reporter, reaction and drug ready to fill in.
Limits to know
- XML imported as XML is passed through unchanged.
- E2B XML export currently leaves out patient weight, patient height and drug dosage text, even when they are filled in. They are kept in the JSON export. Check these fields before using an exported XML.
- PDF import is built for PDFs exported from EudraVigilance. It does not read back the compact PDF this tool creates; to move a case between tools, use XML, HTML, RTF or JSON.
- Converting HTML, RTF or PDF to XML keeps MedDRA terms and version but not numeric codes, so that XML is fine to read but not for EudraVigilance gateway submission.
- PDF import reads the compact EudraVigilance form by column position. It recovers identification, patient, reactions and drugs; MedDRA codes and native-language terms are not in that form and cannot be recovered.
- E2B(R2) import has not been checked against a real R2 export. Every R2 import carries a warning; check recovered fields against the source.
- The CIOMS I form leaves patient initials, date of birth and "did the reaction abate after stopping the drug?" blank, because the data model does not hold them. Seriousness, rechallenge, report source and report type are asked once per case on CIOMS I but held per reaction or drug in E2B, so they are combined.
PDF output uses pdf-lib (MIT License), bundled in the app. The CIOMS I PDF fills the standard CIOMS form I template, served from this site.